1.
Biomed Phys Eng Express ; 9(1)2022 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-36541531

RESUMO

Objectives. The purpose of this study is to present data from the clinical commissioning of an Xstrahl 150 x-ray unit used for superficial radiotherapy,Methods. Commissioning tasks included vendor acceptance tests, timer reproducibility, linearity and end-effect measurements, half-value layer (HVL) measurements, inverse square law verification, head-leakage measurements, and beam output calibration. In addition, percent depth dose (PDD) curves were determined for different combinations of filter/kV settings and applicators. Automated PDD water phantom scans were performed utilizing four contemporary detectors: a microDiamond detector, a microSilicon detector, an EDGE detector, and a PinPoint ionization chamber. The measured PDD data were compared to the published values in BJR Supplement 25,Results. The x-ray unit's mechanical, safety, and radiation characteristics were within vendor-stated specifications. Across sixty commissioned x-ray beams, the PDDs determined in water using solid state detectors were in excellent agreement with the BJR 25 data. For the lower (<100 kVp) and medium-energy (≥100 kVp) superficial beams the average agreement was within [-3.6,+0.4]% and [-3.7,+1.4]% range, respectively. For the high-energy superficial (low-energy orthovoltage) x-rays at 150 kVp, the average difference for the largest 20 × 20 cm2collimator was (-0.7 ± 1.0)%,Conclusions. This study presents machine characterization data collected for clinical use of a superficial x-ray unit. Special focus was placed on utilizing contemporary detectors and techniques for the relative PDD measurements using a motorized water phantom. The results in this study confirm that the aggregate values published in the BJR 25 report still serve as a valid benchmark when comparing data from site-specific measurements, or the reference data for clinical utilization without such measurements,Advances in knowledge. This paper presents comprehensive data from the acceptance and commissioning of a modern kilovoltage superficial x-ray radiotherapy machine. Comparisons between the PDD data measured in this study using different detectors and BJR 25 data are highlighted.


Assuntos
Água , Raios X , Reprodutibilidade dos Testes
2.
Cancer Med ; 7(8): 3642-3651, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29963760

RESUMO

Modern PET/CT radiotherapy simulators offer FDG-PET and dynamic contrast-enhanced (DCE) CT imaging for combined volumetric assessment of tumor metabolism and perfusion. However, the clinical utility of such assessment has not been clearly defined. Thus, in a prospective longitudinal study of primary cervical tumors treated with concurrent chemoradiotherapy (CCRT) we evaluated: (1) whether PET and perfusion parameters correlate or provide complementary information; (2) what imaging changes occur during CCRT; and (3) whether any parameters are predictive of treatment response as assessed by PET/CT 3 months posttherapy. FDG-PET/CT and DCE-CT scans were performed on 21 patients prior to and during CCRT. Coregistered volumetric parametric maps of standardized uptake value (SUV) measures and perfusion parameters blood flow (BF), blood volume (BV), and permeability were generated. Summary statistics for these parameters and their changes were calculated within the metabolic tumor volume (MTV). Correlations between SUV and BF/BV/permeability on local and global bases were assessed with Pearson's coefficient r. MTV, maximum SUV, and mean SUV decreased significantly between the pre- and during-treatment time points, while mean BV and permeability increased significantly. Global correlations between mean BF/BV/permeability and mean SUV values (-.15 < r < .29) were at most moderate. An increase in mean tumor BV during treatment was significantly correlated with complete metabolic response on 3-month posttreatment PET/CT. Weak correlations of SUV and perfusion parameters suggest a complementary role of FDG-PET and DCE-CT for tumor characterization. The association between relative change in mean BV and outcome suggests a potential role for DCE-CT in early evaluation of cervical tumor response to chemoradiotherapy.


Assuntos
Fluordesoxiglucose F18 , Aumento da Imagem , Neovascularização Patológica/diagnóstico por imagem , Neovascularização Patológica/terapia , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/terapia , Adulto , Idoso , Volume Sanguíneo , Quimiorradioterapia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...